柴油發(fā)電機控制器系統(tǒng)由磁電機、低壓電纜、焚燒線圈、高壓電纜、火花塞及焚燒開關組成磁電機的結(jié)構與裝置磁電機系無觸點式工作過程中無火花呈現(xiàn)到達防爆要求輸出電壓力160-180v DC)從A方向看驅(qū)動盤的旋轉(zhuǎn)方向為逆時針發(fā)電機控制模塊驅(qū)動盤滾動三轉(zhuǎn)完結(jié)發(fā)動機的一個作業(yè)循環(huán)即它與曲軸的轉(zhuǎn)速比為1.5:1柴油發(fā)電機組供給的低壓電能貯存于電容器7中當由減速齒輪帶動旋轉(zhuǎn)的守時分配臂6經(jīng)傳感器線圈時即按次序激起SCR電子開關使電容器的能量傳遞到焚燒線圈由此產(chǎn)生的高壓電使火花塞跳火自啟動控制器裝置磁電機前首要須滾動飛輪使榜首缸處于焚燒提早角方位上止點前32曲軸轉(zhuǎn)角磁電機尾端設有調(diào)查孔可看到隨軸旋轉(zhuǎn)的紅線符號及殼體上白CCW字下面的紅線符號然后滾動磁電機的驅(qū)動盤使兩條紅線符號成一條直線發(fā)電機組控制器即可把磁電機裝機擰緊與傳動裝置銜接的兩個螺釘這時焚燒提早角為近似值準確的焚燒提早角的調(diào)整辦法
The diesel generator controller system consists of magneto, low-voltage cable, incineration coil, high-voltage cable The structure and device of magneto are composed of spark plug and incineration switch. The magneto system is contactless. In the process of working, there is no spark to meet the explosion-proof requirements. The output electric pressure is 160-180v DC). From the direction of a, the rotation direction of the driving wheel is counterclockwise. The driving wheel of the generator control module rolls for three turns to complete an operating cycle of the engine, that is, the speed ratio between it and the crankshaft is 1.5:1 supplied by the diesel generator set The low-voltage electric energy is stored in the capacitor 7. When the rotating punctual distribution arm 6 driven by the reduction gear passes through the sensor coil, it will excite the SCR electronic switch in order to transfer the energy of the electric container to the incineration coil. The resulting high-voltage electricity will cause the spark plug to jump. Before starting the magneto of the controller device, the flywheel must be rolled to make the top cylinder 32 crankshaft angle magnetoelectricity before the top dead center of the incineration advance angle azimuth An investigation hole is set at the tail end of the machine to see the red line symbol rotating with the shaft and the red line symbol under the white CCW word on the shell, and then roll the drive disk of the magneto to make the two red line symbols into a straight line. The generator unit controller can install the magneto and tighten the two screws connected with the transmission device. At this time, the incineration advance angle is an approximate value and an accurate adjustment method of the incineration advance angle
松開磁電機與傳動裝置的兩個螺釘發(fā)電機控制屏磁電機可沿傳動軸線滾動發(fā)電機電子調(diào)速器磁電機由中間方位向自由端方向滾動至大的方位時焚燒提早角滯后約10曲軸轉(zhuǎn)角左右反之向輸出端滾動至大方位時柴油發(fā)電機組控制器焚燒提早角提早約10曲軸轉(zhuǎn)角左右柴油發(fā)電機工作時銜接磁電機的2個螺釘要確保擰緊
Loosen the two screws between the magneto and the transmission device. The magneto on the generator control panel can roll along the transmission axis. When the magneto of the generator electronic governor rolls from the middle direction to the free end to the maximum direction, the incineration advance angle lags about 10 crankshaft angle. On the contrary, when rolling to the output end to the maximum direction, the incineration advance angle of the diesel generator set controller is about 10 crankshaft angle Ensure that the two screws connecting the magneto are tightened when the oil generator is working
磁電機裝上低壓電纜插頭引出14根低壓電線每根電線均標示不同符號依照發(fā)火次序與每個氣缸的焚燒線圈+極聯(lián)接符號N的電線與每排缸的焚燒線圈一極串聯(lián)而且兩排缸并聯(lián)符號G的電線與焚燒開關銜接其接線方法為發(fā)電機配件斷路時發(fā)動機工作接地時則發(fā)動機停車
The magneto is equipped with a low-voltage cable plug to lead out 14 low-voltage wires. Each wire is marked with different symbols. According to the firing order, it is connected with the incineration coil + pole of each cylinder. The wire of symbol n is connected in series with one pole of the incineration coil of each row of cylinders, and the wire of symbol g in parallel of the two rows of cylinders is connected with the incineration switch. The wiring method is that the engine stops when the generator accessories are open circuit and the engine is grounded
低壓電纜經(jīng)過低壓電纜把磁電機輸出的電能傳遞到焚燒線圈不同類型的磁電機要配相應標準的低壓電纜由插頭引出的一股電纜內(nèi)每根電線均標示不同的符號根據(jù)發(fā)動機的發(fā)火次序把每根電線銜接到對應氣缸的焚燒線圈的正極、負極焚燒開關及接地等
The low-voltage cable transmits the electric energy output by the magneto to the incineration coil through the low-voltage cable. Different types of magnetos shall be equipped with corresponding standard low-voltage cables. Each wire in a cable led out from the plug shall be marked with different symbols. Each wire shall be connected to the positive and negative incineration switches and grounding of the incineration coil of the corresponding cylinder according to the ignition sequence of the engine
焚燒線圈焚燒線圈將磁電機輸出的低壓電轉(zhuǎn)變?yōu)楦邏弘姲l(fā)電機調(diào)速器不同類型的磁電機應配相應標準的焚燒線圈本機所用焚燒線圈高輸出電壓為40000VDC)當輸出電壓為10000V時火花塞跳火持續(xù)時間為550微秒正、負南北極與電線聯(lián)接時要把螺帽擰緊
Incineration coil incineration coil converts the low-voltage power output by the magneto into high-voltage electric generator governor. Different types of magneto shall be equipped with corresponding standard incineration coil. The maximum output voltage of the incineration coil used by this machine is 40000 VDC). When the output voltage is 10000 V, the duration of spark plug ignition is 550 microseconds. When the positive and negative south north poles are connected with the wire, tighten the nut
火花塞火花塞螺紋為M18×1.5mm裝入缸頭時其扭緊力矩為42-52N.m擰緊后應確?;鸹ㄈ撞康穆菁y端面與缸蓋底面平齊火花塞空隙為0. 6mm當空隙值增大到0.89mm時火花塞將呈現(xiàn)失火現(xiàn)象使發(fā)動機工作不穩(wěn)甚至停車發(fā)電機控制器要求按不同的運用條件定時查看火花塞清除火花塞及其螺紋處呈現(xiàn)的積炭
Spark plug the spark plug thread is M18 × When 1.5mm is installed into the cylinder head, the tightening torque is 42-52n. M. after tightening, ensure that the threaded end face at the bottom of the spark plug is flush with the bottom of the cylinder head. The gap of the spark plug is 0.6mm. When the gap value increases to 0.89mm, the spark plug will show misfire, making the engine unstable and even stopping the generator. The controller requires to regularly check the spark plug according to different application conditions and remove the carbon deposits at the spark plug and its threads